📑 User Manual Navigation
1. Overview & Technical Capabilities
OnlineQC™ is The Concrete Advantage’s engineering-backed, cloud-synchronized quality control portal developed specifically for ready-mix concrete producers, quality assurance directors, plant managers, and testing engineers. With 39 years of real-world ready-mix QC expertise embedded into its algorithms, OnlineQC protects producers against costly backcharges, automates submittal packages, tracks mix trend deviations, and actively identifies cement optimization opportunities that drive bottom-line savings.
Core Operational Modules:
- Live Compressive Strength Tracking: Centralized real-time tracking of early (1–3d), 7-day, 28-day, and 56-day cylinder breaks with historical moving averages.
- Automated ACI 318 / ACI 301 Mix Submittal Packages: One-click generation of fully compliant 30-consecutive-test submittal packages with standard deviation, moving averages, and Gaussian bell-curve distributions.
- Proactive Low Break Risk Management: Automated dual-rule compliance monitoring per ACI 318-19 Section 26.12.1.1 with root cause correlation (water addition, high air, cold weather curing).
- Direct Lab PDF Intake & OCR Verification: Streamlined ingestion of testing lab PDF sheets (Terracon, ECS, PSI, Froehling & Robertson, regional labs) with side-by-side QA verification before committing to active records.
- Economic Cement Optimization Engine: Continuously monitors mix overdesign above ACI required average strength (f'cr), pinpointing mixes with >500 psi excess strength where cementitious reduction will yield safe financial and carbon savings.
2. Authentication, Account Management & Multi-Tenant Isolation
OnlineQC utilizes a zero-bleed, multi-tenant customer isolation architecture. Each ready-mix producer accesses a dedicated, encrypted workspace containing only their mix catalog, customer projects, delivery tickets, and cylinder break results.
2.1 Signing In
- Navigate to the OnlineQC portal URL in any modern desktop or mobile browser.
- Enter your authorized Company Email or Username (e.g.,
hill@feltonbrothers.comorfelton). - Enter your assigned confidential Password.
- Optionally check "Remember Me" to securely preserve your active login session on your workstation.
- Click "Sign In to OnlineQC Portal →".
3. Main Navigation & Header Suite
- ▦ TCA SUITE APPS Menu: Quick-launch access to integrated tools including the ACI 301 Mix Designer, the Concrete Plant Pre-Inspection & DOT Audit, and the TCA Engineering Calculators.
- Active Organization Selector: Displays your producer organization name. Users with multi-plant or certifier privileges can switch between regional plant profiles seamlessly.
- ☁️ Cloud Synced Indicator: Real-time status heartbeat indicating active synchronization with the Supabase PostgreSQL cloud repository.
- Red Primary Navigation Bar: Instant single-click switching between the primary operational workspaces without reloading the page.
4. Tab 1: Strength Summary & Mix Catalog (Deep Dive)
The Strength Summary tab is the operational command center of OnlineQC. It delivers a comprehensive overview of every active concrete mix produced, summarizing compressive strength gains, fresh properties, statistical standard deviation, overdesign margins, and compliance statuses.
4.1 Top KPI Summary Cards
Located above the mix catalog, four top-level summary metrics provide immediate quality visibility:
- Active Mixes: Total count of commercial mix designs registered and active in your producer database.
- Verified Strength Tests: Total cumulative cylinder break reports ingested, verified, and active in the database.
- Non-Compliant Mixes: Number of mixes currently exhibiting confirmed cylinder breaks below specified design strength (f'c).
- Active Low Break Alerts: Count of uninvestigated or pending low break alerts requiring engineering root cause determination.
4.2 The Mix Catalog Master Table
| Column Header | Display Element | Engineering Definition & Calculation Method |
|---|---|---|
| Mix No. | Producer Mix ID & Tags | The unique producer product code (e.g., 35NA30, 45AE30A). Clicking the code drills into the Mix Details & Ticket Explorer. Displays a green 🌱 Opt pill when eligible for cement optimization. |
| Mix Description | Application & Class | Descriptive name and structural application (e.g., 3500 PSI Foundation & Slab Mix, 4500 PSI Commercial Air). |
| f'c Spec | Specified Strength (psi) | Design specified 28-day compressive strength required by project structural drawings. |
| 28d Tests (N) | Cohort Sample Size | Number of verified 28-day break tests evaluated in the moving cohort (capped at the most recent 45 tests). |
| Avg Slump | Field Workability (in.) | Average field slump measured at jobsite discharge across the moving 45-test cohort. |
| Avg Air | Entrained Air (%) | Average field air content measured via pressure meter (ASTM C231) across the moving cohort. |
| Avg Temp | Fresh Temp (°F) | Average concrete placement temperature measured per ASTM C1064 across the moving cohort. |
| Avg 7-Day | Early Strength (psi) | Average 7-day compressive strength across tickets in the moving 45-test cohort that have recorded 7-day breaks. |
| Avg 28-Day | Design Strength (psi) | Arithmetic mean of all 28-day cylinder breaks in the moving 45-test cohort. Displayed in red if below f'c. |
| Overdesign | Variance vs. ACI f'cr | Difference between actual 28-day average strength and required ACI 318 strength (Avg 28d - f'cr). Highlighted in green with 🌱 >500 psi Opt badge when exceeding required strength by >500 psi. |
| Gain (7→28) | Strength Increase (psi) | Actual compressive strength gain from 7 to 28 days (Avg 28d - Avg 7d). Key indicator of pozzolanic hydration and cement reactivity. |
| Std Dev (Ss) | Sample Std Dev (psi) | Sample standard deviation calculated per ACI 214R across the moving 45-test cohort. |
| Status | Compliance Badge | The automated quality and compliance status badge evaluating ACI 318 criteria, low breaks, pending tests, and optimization opportunities. |
4.3 Requirements & Evaluation Logic for Mix Summary Statuses
Every active mix is evaluated in real time against a rigorous, prioritized compliance hierarchy. OnlineQC inspects test break values, standard deviations, required average overdesign, active alerts, and test maturation schedules to assign one of six distinct statuses:
| Status Badge | Priority | Triggering Conditions & Technical Requirements | Operational Action Protocol |
|---|---|---|---|
|
🚨 Non-Compliant (X Low Breaks < f'c) |
1 (Highest) |
Condition: stats.hasLowBreaks === trueTriggered whenever one or more verified 28-day cylinder strength tests in the moving 45-test cohort fail to reach the specified design strength: Individual Break Test < Specified f'c
Example: A 3,500 psi mix has a verified 28-day break of 3,180 psi. |
Immediate Producer Action:
|
|
⚠️ Below f'cr (Avg < f'cr psi) |
2 |
Condition: stats.isBelowFcr === trueTriggered when there are zero individual breaks below f'c, but the cohort 28-day arithmetic mean falls below the ACI 318 required average strength (f'cr): Average 28d Strength < Required f'cr
The mix meets bare minimum strength on every ticket but lacks adequate statistical safety margin required by ACI 318 Table 26.4.3.1(b). |
Preventative QC Action:
|
| ⚠️ X Active Alerts | 3 |
Condition: stats.lowBreakCount > 0Triggered when open, unresolved low break incident reports exist in the low break investigation queue for this mix, but confirmed cylinder breaks have not yet entered the primary moving cohort. |
Investigation Action:
|
| 🌱 Potential Optimization | 4 |
Condition: stats.isPotentialOptimization === trueTriggered when ALL of the following criteria are satisfied:
🌱 Opt badge is placed on the mix ID.
|
Cost & Cement Optimization Action:
|
| ⏳ X Pending 28d | 5 |
Condition: stats.pending7dCount > 0Triggered when a mix has test records with valid 7-day breaks recorded (avg7d > 0), but the corresponding 28-day cylinder tests have not yet occurred or been entered. Note: Pending tickets are displayed in Mix Details for producer visibility, but are properly excluded from summary moving averages until 28-day break results mature. |
Schedule Tracking:
|
| ✓ Compliant | 6 (Normal) |
Condition: Default compliant state. All 28-day strength tests equal or exceed specified f'c, the 28-day average satisfies ACI required f'cr, there are zero active alerts, and overdesign is within the optimal operating range (+0 to +500 psi above f'cr). |
Routine Monitoring:
|
4.4 The 45-Test Moving Average Cohort Methodology
Unlike simplistic systems that lump together years of outdated break data, OnlineQC implements a 45-test moving average cohort. All summary averages—including Slump, Air, Concrete Temperature, 7-Day Strength, 28-Day Strength, 56-Day Strength, Standard Deviation (Ss), and Overdesign—are calculated strictly on up to the most recent 45 consecutive tests of that mix that have verified 28-day results.
Standard Deviation (Ss) Calculation per ACI 214R:
Where Xi is individual 28-day strength test, X̄ is the cohort mean, and N is the cohort sample count.
Required Average Strength (f'cr) per ACI 318-19 Table 26.4.3.1(b):
4.5 Mix Details & Ticket Explorer
Clicking any mix number in the master table opens the Mix Details & Ticket Explorer:
- Mix Specification Header: Displays specified slump, air content range, design f'c, and theoretical unit weight.
- Filter Tickets: Filter the ticket list by
Active tickets (Included in Summary),Show all tickets, orShow omitted tickets only. - Optional Column Toggles: Show or hide
Avg 56 Daybreaks andUnit Weightcolumns. - Export Historical Submittal Sheet: Generates a printable submittal sheet listing all 45 cohort tickets, moving averages, and statistical compliance certifications.
- Single-Ticket View: Clicking
viewon any ticket opens the complete digital break certificate, showing cylinder dimensions, break dates, failure loads, ASTM C39 fracture types (Types 1–6), and lab technician notes.
4.6 Ticket Omission & Quality Audit Trail
When a cylinder break is demonstrably invalid due to documented field errors—such as unauthorized jobsite water addition by a contractor, dropped cylinders, cold weather jobsite storage curing violations (ASTM C31), or testing machine calibration failure—producers can initiate a ticket omission request.
- Click "Flag / Omit Ticket" on the ticket view modal.
- Select the formal justification category (e.g., Jobsite Water Addition > Allowable, Cylinder Handling/Curing Damage, Third-Party Lab Procedure Violation).
- Enter supporting field notes and lab report cross-references.
- Upon sign-off by a TCA Quality Certifier, the ticket is omitted from statistical standard deviation and average calculations while remaining permanently preserved in the audit log for complete regulatory transparency.
5. Tab 2: Strength Analysis & ACI 318 Submittal Engine
The Strength Analysis tab provides advanced multi-dimensional statistical filtering and engineering modeling adhering to ACI 318-19 Section 26.4.3 and ACI 214R.
5.1 Multi-Dimensional Filter Engine
Isolate and analyze specific performance variables across your production history:
- Mix Selection Checkboxes: Analyze a single mix or multi-select similar mixes to evaluate aggregate performance.
- Project Directory Checkboxes: Filter breaks strictly for a specific commercial project (e.g., Microsoft LYH10 Data Center) or evaluate all projects combined.
- Date Range Selectors: Evaluate seasonal performance (e.g., Summer mix vs. Winter mix adjustments).
- Fresh Property Slump & Air Sliders: Filter out out-of-spec batches to evaluate baseline design performance.
5.2 ACI 214 Statistical Evaluation Panel
The calculation engine computes comprehensive quality control metrics instantly:
| Metric | Formula / Origin | ACI 214 Quality Standard Interpretation |
|---|---|---|
| Coefficient of Variation (V) | V = (ss / X̄) × 100% |
< 10.0%: Excellent plant control. 10.0% – 12.0%: Very Good plant control. 12.0% – 15.0%: Good (Normal) plant control. 15.0% – 18.0%: Fair plant control. > 18.0%: Poor control — batching review required. |
| Required Strength (f'cr) | ACI 318 Table 26.4.3.1(b) | Minimum target average compressive strength required to ensure ≤ 1 in 100 chance of low breaks. |
| Overdesign Margin | X̄ - f'cr | Actual safety margin in PSI. Values > 500 psi indicate opportunity for cementitious reduction. |
5.3 Interactive Charts & Visualizations
- Strength vs. Age Progression Curve: Compares early 1-day, 3-day, 7-day, 28-day, and 56-day progression curves against the specified design strength line.
- Moving Average of 3 Consecutive Tests: Trendline tracking consecutive 3-test moving averages directly against the f'c compliance threshold per ACI 318.
- Gaussian Strength Distribution Bell Curve: Statistical histogram displaying normal distribution bell-curve fitted over individual strength test frequencies, showing standard deviation lines and specified f'c cutoffs.
5.4 Saved Submittal Query Presets
Save frequently required contractor or DOT submittal parameters:
- Set your desired mix, project, and date filters.
- Click "💾 Save Analysis Query".
- Name the query (e.g., 35NA30 - Microsoft LYH10 Foundation Submittal).
- The query snapshot is saved to your organization profile. Click the preset name at any time to instantly reload those exact filters.
6. Tab 3: Low Break Alerts & Root Cause Diagnostic Engine
OnlineQC continuously audits every cylinder break against ACI 318-19 Section 26.12.1.1 concrete acceptance criteria:
No individual strength test (average of two 6x12" or three 4x8" cylinders) falls below f'c by more than 500 psi (when f'c ≤ 5,000 psi) or by more than 0.10 f'c (when f'c > 5,000 psi).
Every arithmetic average of any three consecutive strength tests equals or exceeds specified f'c.
6.1 Automated Root Cause Diagnostics
When a cylinder break falls below specified strength, OnlineQC's diagnostic engine analyzes fresh concrete properties from the batch ticket to determine the primary contributing factor:
- Water-Cement Ratio Shift / Slump Anomaly: Flags field slump > 5.5" or recorded jobsite water additions exceeding allowable mix design water.
- Air Entrainment Exceedance: Flags fresh air content > 6.5%. (Rule of thumb: each 1% excess air reduces compressive strength by approximately 5%).
- Low Temperature Placement / Curing: Flags batch or placement temperatures < 50°F indicative of delayed hydration or improper ASTM C31 initial field curing box maintenance.
- Testing Laboratory Anomaly: Flags Type 5 (shear) or Type 6 (columnar) cylinder breaks often caused by unlevel cylinder capping, unplaned ends, or eccentric machine loading.
7. Tab 4: QA Ingest, Lab PDF OCR & Verification Queue
OnlineQC simplifies test report ingestion by allowing producers to submit commercial testing lab PDF break sheets directly into an automated verification queue.
7.1 Submitting Test Reports (Ingestion Protocols)
OnlineQC supports three fast, flexible methods for producers to transmit compressive strength break sheets:
- Method A: Loose PDF Reports: Drag & drop individual PDF files. Recommended batch size: 20 to 25 reports (under 35 MB) for instantaneous cloud sync.
- Method B: Select Entire Folder: Click "📁 Select Folder of Reports" to upload an entire daily project directory without manually clicking each file.
- Method C: Compressed .ZIP Archive: For large project backlogs or quarterly submittals (50 to 300+ reports), right-click your desktop folder → Compress to ZIP and drop the single
.zipfile.
For step-by-step Windows 10/11 right-click zipping instructions, scanner orientation rules, and transfer speed tables, open the official OnlineQC Ingestion Quick Guide & SOP (Printable / PDF) →
- Click "📤 SEND TEST REPORTS TO TCA" (or open the QA review dropzone).
- Drop your PDFs, entire folder, or
.ziparchive into the upload box. - Wait for the Green Checkmark: Always keep your browser tab open until the progress bar reaches 100% and displays "✅ Ingestion Complete" before navigating away.
7.2 Side-by-Side QA Review Lightbox
TCA Certifiers and designated producer QC managers review reports using a split-screen lightbox:
- Left Pane: High-resolution PDF document viewer displaying original laboratory seals and break sheets.
- Right Pane: Extracted editable data form containing batch date, ticket number, cylinder dimensions, break loads, calculated PSI, and fresh properties.
- Approval: Click "✅ Approve & Push to Live Database" to commit the verified tests to your active database in one click.
8. Tab 5: Admin Console & Master Data Management
Accessible to users with administrative credentials, the Admin Console provides management of organization master data:
- Mix Catalog Management: Register new master mix designs, configure specified f'c, target slump, design air, target unit weight, and maximum water-cement ratio.
- Customer Project Directory: Add master construction projects, specify general contractors, and assign authorized mix designs.
- User Accounts & Access Roles: Manage user accounts, role permissions (
customer,admin,certifier), and email aliases. - Cloud Database Backup & Synchronization: Monitor real-time synchronization with the Supabase PostgreSQL cloud backend. OnlineQC implements non-destructive union merging so data is permanently protected against accidental resets.
9. Engineering Toolbox & Suite Integrations
Through the ▦ TCA SUITE APPS dropdown in the top header, producers have instant access to specialized engineering modules:
9.1 ACI 301 Mix Designer Integration
Launch directly into the full-featured ACI 301 Mix Designer web application. The Mix Designer features volumetric absolute volume mix proportioning, 3-point water-cement ratio curve modeling per ACI 301-20 Section 4.2.3, aggregate sieve analysis, and submittal sheet generation scoped to your customer account.
9.2 Concrete Plant Pre-Inspection & DOT Audit Checklist
A comprehensive 12-point inspection module compliant with NRMCA and State DOT plant certification protocols:
- Scales & Calibration Tolerances: Cementitious scale (±1%), Aggregate scale (±2%), Water meter (±1%), Admixture dispensers (±3%).
- Moisture Probes: Daily microwave calibration verification of aggregate moisture sensors.
- Mixer Uniformity: ASTM C94 mixer blade wear inspection and slump uniformity across load.
- DOT Compliance Scorecard: Computes real-time percentage compliance score and generates an audit certification certificate.
9.3 Interactive Engineering Calculators (3 Modules)
-
Plastic Shrinkage Evaporation Rate (ACI 305.1 Nomograph):
Computes predicted evaporation rate E (lb/ft²/hr) from concrete temperature, air temperature, relative humidity, and wind speed using the official ACI 305.1 formula:Flags cracking risk (Safe: <0.10, Moderate: 0.10–0.20, Severe: >0.20 lb/ft²/hr) and outputs required curing precautions.E = 5 × [ (Tc + 18)2.5 - r × (Ta + 18)2.5 ] × (V + 4) × 10-6 -
Water-Soluble / Total Chlorides Calculator (ACI 318 Table 19.3.2.1):
Evaluates chloride ion contributions from cement, mixing water, fine aggregates, coarse aggregates, and admixtures against ACI maximum limits for prestressed concrete (0.06%), reinforced concrete in wet service (0.15%), and dry service (1.00%). -
Concrete Temperature Energy Balance Prediction:
Calculates predicted freshly mixed concrete temperature based on thermal specific heat balance of coarse aggregate, fine aggregate, cement, fly ash/slag, mixing water, and added batch ice.
10. Data Exports, Submittals & FAQs
10.1 Reporting & Export Formats
- Formal ACI Submittal PDF: Generates official producer submittal packages with company letterhead, moving averages, standard deviation charts, and individual cylinder break listings.
- CSV Data Export: Export raw ticket break data for seamless import into Command Alkon, Sysdyne, Marcotte, Jonel, or Microsoft Excel.
- Individual Break Certificates: Print single-ticket ASTM C39 test certificates with fracture type diagrams and technician sign-offs.
10.2 Frequently Asked Questions (FAQ)
Q: How does OnlineQC calculate standard deviation if I have fewer than 30 tests?
A: In accordance with ACI 318 Table 26.4.3.1(a), if fewer than 30 tests are available (between 15 and 29 consecutive tests), the sample standard deviation is multiplied by an ACI modification factor (1.16 for 15 tests, 1.08 for 20 tests, 1.03 for 25 tests, 1.00 for 30+ tests). OnlineQC handles this adjustment automatically in the Strength Analysis module.
Q: How do I know if a mix qualifies for cement optimization?
A: Check the Mix Summary status badge. When a mix achieves the 🌱 Potential Optimization badge (with a green 🌱 Opt pill on the mix code and green row highlighting), its 28-day average strength exceeds the ACI required average strength (f'cr) by more than 500 psi with zero low breaks and at least 30 verified 28-day test reports. This ensures complete statistical confidence per ACI 318 before cement reduction is submitted.
Q: What happens if a contractor adds water on the jobsite?
A: Record the contractor water addition in the ticket details. If the resulting break fails to meet specified f'c, flag the ticket for omission under the "Jobsite Water Addition > Allowable" justification. Once approved by the TCA certifier, the ticket is omitted from the moving 45-test standard deviation calculations to protect your plant compliance record.
Q: Is our data backed up to the cloud?
A: Yes. All data is continuously synchronized with the central Supabase PostgreSQL cloud repository with multi-tier union merge protection to prevent accidental loss or overwrite.
© 2026 The Concrete Advantage. All rights reserved. OnlineQC™ is a proprietary quality control management system.